Qdos 30 pump cut capital equipment costs

Three diaphragm pumps have been replaced with a Qdos peristaltic metering pump in a phosphorous coagulant iron III chloride dosing application

Qdos pumps replace diaphragm pumps in a phosphorous coagulant iron III chloride dosing applicationThe Qdos 30 pump has not only cut capital equipment costs, but introduced significantly reduced maintenance and repair costs at Riepe, in the East Frisia region of Germany.

Diaphragm pump issues

In order to achieve a reduction in the phosphorous levels in the inflow water at Riepe, the waste water facility uses chemical coagulation, which converts the phosphate solution in the water into insoluble phosphate compounds that can then be isolated.

Previously, one diaphragm pump supplied the coagulant from underground storage containers into the holding tank, with the actual dosing handled by two further diaphragm pumps – one in constant use and one in standby mode in the event of a failure. Indeed, failure was an increasingly common outcome as the pump diaphragms were often corroded by the chemical coagulants, making replacement necessary. 

"The diaphragm pumps also produce a strongly pulsating flow which, after some time, would lead to signs of wear and tear on the fittings and valves,” says Riepe Plant Manager, Mr Janssen. “The maintenance work started amounting to several hours per month; moreover, we had to hold a whole range of spare parts in stock, including diaphragms and valves.”

A further problem with the diaphragm pumps was suction. Air would be drawn in, which could jam the valves meaning that the diaphragm pumps were unable to prime and pump. As a result, the phosphorous limits discharged from the plant increased and, in the worst case, meant that the relevant authorities had to be notified.

The problem occurred most often whenever the stock of coagulant was replenished. Here, the chemical dosing lines had to be manually flooded with water to enable the diaphragm pumps to operate.

High phosphate levels? No problem

The Watson-Marlow Qdos 30 peristaltic metering pump at this site doses at 150ml/min, although it offers a maximum flow rate of 500ml/min – more than enough for occasions when there are high phosphate levels in the water. The single Qdos pump is able to draw the iron III chloride directly from the storage tank, which means that a holding pump, the standby pump and, the holding tank, plus associated float switches and electronics, are no longer necessary.

“While the accuracy of the diaphragm pumps declined over time as the diaphragms became corroded and worn, the Qdos pump is extremely accurate, so we’ve able to reduce the frequency of recalibration."

Complete reliability

In total, Mr Janssen estimates that the Qdos pump has led to an impressive time saving of between two and five hours per month. "By relieving us of this workload and the saving on spare parts, the investment has paid off very quickly.”

Find out more about Qdos pumps

  • Find a product

  • Find a local contact

  • Help and advice

    For help or advice please contact us on:

    Tel: +1 978 658 6168 and Toll free +1 800 282-8823

    You can also send us an email or find your nearest distributor